Product Details:
| Volume | 2 L |
| Design Pressure | 40 bar |
| Material | Carbon Steel |
| Connection Size | 15 mm |
| Connection Type | Screwed |
| Orientation | Vertical |
| Usage/Application | Industrial |
| End Standard | ASME B16.11 |
| Finish | Painted |
| Application | Oil, Steam, Chemical, Gas |
Equipment Name: CS IBR Condensate Pot
Purpose / Function:
Collects condensate from steam lines before it reaches sensitive instruments.
Protects pressure gauges, transmitters, and control valves from water hammer and high-temperature steam.
Ensures accurate pressure measurement and smooth operation of steam systems.
IBR Compliance: Designed, fabricated, and tested as per Indian Boiler Regulations (IBR) with IBR certification.
Body & End Caps: Carbon Steel (CS / MS) as per IBR standards.
Drain / Vent Connections: Carbon Steel.
Welding: IBR-approved welding procedures (SMAW / TIG / MIG as applicable).
Corrosion Protection:
Internal: Carbon steel with corrosion allowance or internal coating if required.
External: Paint or epoxy coating for atmospheric protection.
Vertical cylindrical or bottle-type vessel.
Inlet: Top or side from steam line.
Outlet: To instrument, drain line, or condensate return line.
Drain: Bottom drain for manual or automatic condensate removal.
Vent: Optional top vent for air or non-condensable gases.
Wall or pipe-mounted support for stability.
Suitable for high-pressure and high-temperature steam service.
| Parameter | Specification |
|---|---|
| Nominal Size | 2" – 6" NB (custom sizes available) |
| Schedule / Thickness | As per IBR design / SCH 40 equivalent |
| Design Pressure | As per IBR & process requirement |
| Design Temperature | Up to 550°C |
| End Connections | NPT / BSP / Socket Weld / Butt Weld |
| Inspection / Testing | Hydrostatic test as per IBR; PMI, radiography & visual inspection |
| Certification | IBR-approved with Material Test Certificates (MTC) |
Steam boiler lines and auxiliaries.
Protection of pressure gauges, transmitters, and control valves.
Condensate collection from turbines, heat exchangers, and process lines.
Power plants, chemical plants, and petrochemical industries.
Product Details:
| Minimum Order Quantity | 10 Piece |
| Volume | 2 L |
| Design Pressure | 25 bar |
| Material | P22 |
| Connection Size | 15 mm |
| Connection Type | Screwed |
| Orientation | Vertical |
| End Standard | ASME B16.11 |
| Finish | Painted |
| Application | Gas, Oil, Steam, Chemical |
| Brand | KALPATARU |
A P22 condensate pot is a condensate collection and discharge vessel used in steam systems (common in HVAC, boilers, and industrial plants).
What it does
Collects condensate (water formed when steam cools)
Allows condensate to be drained safely without releasing live steam
Helps protect equipment and improve system efficiency
Typical features
Steel pressure-rated pot (often carbon steel)
Inlet from steam line or equipment
Outlet to a steam trap
Drain and vent connections
Designed for specific pressure and temperature ranges
Common uses
Steam tracing systems
Heat exchangers
Drip legs on steam mains
Boiler auxiliary lines
Product Details:
| Volume | 3 L |
| Design Pressure | 10 bar |
| Material | Carbon Steel |
| Connection Size | 15 mm |
| Connection Type | Screwed |
| Orientation | Horizontal |
| End Standard | ASME B16.5 |
| Finish | Painted |
| Application | Gas, Steam, Oil, Chemical |
| Brand | KALPATARU pipe and fittings |
A Boiler Condensate Pot is a pressure-rated collection vessel used in steam boiler systems to collect and drain condensate from steam lines before it reaches instruments, valves, or the boiler itself. It prevents water hammer, measurement errors, and damage to sensitive equipment caused by condensate or flash steam.
Material of ConstructionBody: Carbon Steel, Stainless Steel SS 304 / SS 316
End Caps / Covers: Welded or flanged
Drain / Vent Connections: Same material as body
Optional: Duplex stainless steel for corrosive steam or chemical environments
Purpose / FunctionCollects condensate from steam lines and boiler auxiliaries
Protects instruments like pressure gauges and transmitters
Prevents hot steam or water slug from entering sensitive equipment
Ensures accurate pressure measurement and stable boiler operation
Vertical cylindrical or bottle-type design
Inlet: Top or side from boiler steam line
Outlet: To instrument or condensate return line
Drain: Bottom drain for manual or automatic condensate removal
Vent: Optional top vent for air or non-condensable gases
Wall or pipe mounting bracket for support
Size: 2" NB – 6" NB (custom sizes available)
Schedule: SCH 40 / SCH 80
Pressure Rating: 1500 – 6000 psi (depending on design)
Temperature Rating: Up to ~550°C
End Connections: NPT / BSP threaded, Socket weld, or Butt weld
Steam boilers and steam distribution lines
Boiler instrumentation protection (gauges, transmitters)
Heat exchangers, turbines, and auxiliary equipment
Power plants, chemical, and petrochemical industries
Product Details:
| Minimum Order Quantity | 10 Piece |
| Volume | 3 L |
| Design Pressure | 100 bar |
| Material | Carbon Steel |
| Connection Size | 15 mm |
| Connection Type | Screwed |
| Orientation | Vertical |
| Application | Gas, Steam, Chemical, Oil |
Equipment Name: MS IBR Condensate Pot
Purpose / Function:
Collects condensate from steam lines before it reaches instruments or valves.
Protects instruments such as pressure gauges, transmitters, and control valves from water hammer and high-temperature steam.
Ensures accurate pressure measurement and safe boiler operation.
IBR Compliance: Designed and manufactured as per Indian Boiler Regulations (IBR) with necessary certification.
Body & End Caps: Mild Steel (MS) as per IBR standards
Drain / Vent Connections: MS
Welding: IBR-approved welding procedures
Corrosion Protection:
Internal: Carbon steel with corrosion allowance or internal coating if required
External: Paint / epoxy coating for atmospheric corrosion resistance
Vertical cylindrical or bottle-type vessel
Inlet: Top or side from steam line
Outlet: To instrument, drain line, or condensate return line
Drain: Bottom drain (manual or automatic)
Vent: Optional top vent for air / non-condensable gases
Wall or pipe-mounted support for stability
Designed for high-pressure and high-temperature steam service
| Parameter | Specification |
|---|---|
| Nominal Size | 2" – 6" NB (custom sizes available) |
| Schedule / Thickness | As per IBR design / SCH 40 equivalent |
| Design Pressure | As per IBR & process requirement |
| Design Temperature | Up to 550°C |
| End Connections | NPT / BSP / Socket Weld / Butt Weld |
| Inspection / Testing | Hydrostatic test as per IBR; PMI and radiography if required |
| Certification | IBR-approved with Material Test Certificates (MTC) |
Steam boiler lines and auxiliaries
Pressure gauges, transmitters, and control valves protection
Heat exchangers, turbines, and condensate collection systems
Power plants, chemical plants, and petrochemical industries
Product Details:
| Volume | 3 L |
| Design Pressure | 10 bar |
| Material | Stainless Steel 316 |
| Connection Size | 15 mm |
| Connection Type | Screwed |
| Orientation | Horizontal |
| End Standard | ASME B16.5 |
| Application | Oil, Chemical, Steam, Gas |